.gif)
Nondestructive Testing |
|
CASE STUDIES |
Weld Root Erosion
Application
- Process & transport piping systems
- Chemical attack causing structural breakdown of sensitised
area of weld adjacent parent metal
- Affected material eroded by product flow
Technique
- Conventional (zero degree compression wave) WT measurement
techniques inappropriate because defects unfavourably position
& orientated
- TOFD/R profiling offers most effective, comprehensive &
efficient solution for detection & residual WT measurement

Result
Fast, efficient, reliable, repeatable, non-invasive, safe,
high POD, non-comparative, residual wt value, immediate graphical
results, hard copy evidence
|